Elitech HVAC Refrigerant Infrared Leak Detector Advanced Freon Tester ILD-200
Elitech HVAC 냉매 적외선 누설 탐지기 고급 프레온 테스터 ILD-200
| 상품번호 | 272828711481 |
| 상태 | New |
| 거래유형 | 즉시구매 |
| 출고국 | 영국 (GB) |
상품 설명
Elitech ILD-200
Infrared Refrigerant Leak Detector
Next‑gen NDIR sensor · 0.14 oz/yr sensitivity · 10‑year sensor life · Built for HVAC/R professionals
Why infrared outperforms traditional heated diode?
Conventional sensors degrade over time and react to contaminants. Elitech's non-dispersive infrared (NDIR) sensor delivers unwavering accuracy, 10+ years of stable performance, and selective detection of CFC, HFC, HCFC, and HFO refrigerants. Perfect for R22, R410A, R32, R1234yf and more.
✅ Immune to contamination
Dust, moisture, and oil mist won’t trigger false alarms.🔁 Never degrades
No sensitivity loss over time — factory calibrated.🌍 Eco‑friendly
Find micro leaks quickly to reduce refrigerant emissions.| Auto OFF | 10 minutes without operation (power-saving) |
|---|---|
| Operating Temperature | -10°C to 52°C (14°F to 125.6°F) |
| Operating Humidity | 50%~85%RH (non-condensing, infrared resistant) |
| Storage Temperature | -20°C to 60°C (-4°F to 140°F) |
| Weight | 0.93 lbs (ultra-light, one-hand operation) |
| Dimensions | 7.9 × 3.3 × 1.5 inches |
| Battery | 3.7V 3000mAh Li-ion · 6h continuous use · USB-C charging |
| Sensor Life | 10 years (non-dispersive infrared, zero degradation) |
|---|---|
| Max Sensitivity | 0.14 oz/yr (4 g/year) — detects micro leaks instantly |
| Response Time | ≤ 1 second |
| Preheating Time | 30 seconds (fast ready) |
| Refrigerant Types | CFC / HFC / HCFC / HFO (R22, R134a, R404A, R410A, R32, R1234yf, etc.) |
| Display | 2.8" TFT LCD (real‑time concentration & battery status) |
| Alarm | Audio, visual bar graph, vibration — three modes |
| Model | ILD-200 | IR-200 | Inframate C | LD-100+ |
|---|---|---|---|---|
| Product | ![]() ILD-200 |
![]() IR-200 |
![]() Inframate C |
![]() LD-100+ |
| Sensor Type | Infrared (NDIR) | Infrared + Heated Diode | Infrared (CO₂) | Heated Diode |
| Sensor Life | ≥10 years | ≥10 yrs / 2 yrs | ≥ 40,000 hrs | ≥ 500 hrs |
| Probe Length | 15.5 inch | 10 inch ×2 (extended) | 10 inch | 16.5 inch |
| HFCs | ✅ | ✅ | — | ✅ |
| HCFCs | ✅ | ✅ | — | ✅ |
| CFCs | ✅ | ✅ | — | ✅ |
| HFOs | ✅ | ✅ | — | ✅ |
| HCs (R290) | — | ✅ | — | ✅ |
| R744 (CO₂) | — | — | ✅ | — |

Large 2.8" TFT Color Display
Real-time gas concentration curve, battery level, sensitivity level, and alarm status at a glance. One of the few detectors on the market with such an intuitive interface — no more guesswork.
UV Light & Replaceable Filters
Package includes a professional UV light for fluorescent dye verification and 10 spare filters to keep the sensor clean in dusty environments. Perfect for commercial refrigeration and automotive AC.

3 Adjustable Sensitivity Levels
Switch between High / Medium / Low to pinpoint leaks faster. High sensitivity for tiny leaks, low sensitivity to narrow down the exact spot in high concentration areas. Responds in less than a second.
Ideal for AC, refrigeration, automotive, and industrial HVAC/R systems

What's in the Box
- 1x ILD-200 Infrared Leak Detector
- 1x UV Light (for fluorescent dye detection)
- 1x USB Charging Cable (Type-C)
- 10x Replacement Filters
- 1x Sturdy Carrying Case
- Quick Start Guide
Everything you need to start detecting leaks immediately — no extra purchases required.
✔️ Upgrade your leak detection workflow
Stop wasting time with unreliable tools. Elitech ILD-200 delivers pinpoint accuracy, 10-year sensor durability, and effortless operation. Backed by 1‑year warranty and expert support.
Get the ILD-200 →Designed for HVAC/R professionals who demand the best.





