The Agilent 8453 diode-array UV-Vis spectrophotometer captures the full spectrum in a fast scan, delivering results in under a second without moving optical parts. Its single-beam design supports stable measurements with low noise and strong run-to-run reproducibility. The system includes GLP-ready features such as time and date stamping via an internal clock, along with built-in self-test routines to support routine verification. A compact footprint and open sample area make it easy to load samples and accommodate common accessories like cell holders, multi-cell transports, and sipper systems. Control is handled through a PC using ChemStation software for method setup, acquisition, and reporting.
Specifications:
| Wavelength range | 190–1100 nm |
| Slit width | 1 nm |
| EP resolution test | > 1.6 toluene in hexane, ratio abs. at 269 nm/266 nm |
| Stray light | < 0.03 % at 340 nm (NaNO2, ASTM)
< 0.05 % at 220 nm (NaI, ASTM) < 1 % at 198 nm (KCl, EP) |
| Wavelength accuracy | < ± 0.5 nm 0.5-second scan (NIST 2034)
< ± 0.2 nm at 486.0 and 656.1 nm |
| Wavelength reproducibility | < ± 0.02 nm ten consecutive scans (NIST 2034) |
| Photometric accuracy | < ± 0.005 A at 440.0, 465.0, 546.1, 590.0, and 635.0 nm, 1 A (NIST 930e)
< ± 0.01 A at 235, 257, 313, 350, 430 nm, (potassium dichromate, EP method) |
| Photometric noise | < 0.0002 A sixty 0.5 second scans at 0 A, 500 nm, rms |
| Photometric noise | < 0.0002 A sixty 0.5 second scans at 0 A, 500 nm, rms |
| Photometric stability | < 0.001 A/h at 0 A, 340 nm, after 1-hour warm up, measured over 1 hour, every 5 seconds, constant ambient temp. |
| Baseline flatness | < 0.001 A 0.5-second blank, 0.5-second scan, rms |
| Typical scan time | 1.5 second full range |
| Shortest scan time | 0.1 second full range |
| Time until next scan | 0.1 second full range, 0.1-second scan, up to 150 consecutive scans |
| Dimensions | 24x16x8” |
| Weight | 50lbs |
| Power | 100-120/220-240V, 50/60 Hz |
Includes:
- Agilent 8453 UV-Vis Spectrophotometer
- Windows 10 Notebook Running UV-Vis ChemStation
- System Validation Reports with Clean Bill of Health
- NEW UV Lamp Installed
- NEW Visible (VIS) Lamp Installed
- Single Cell Sample Holder
- Communication Cable
- User Manual
- 120V Power Cord (3A)
- 30-Day Warranty
Disclaimer: Please note any thermometers, gas supply tanks, regulators, or data-loggers seen in our photos is not included unless otherwise noted in the listing. This is our testing tools to show buyer(s) the instrument is working properly up to manufacturer specification and has been tested by our service department. If you see something and have questions please don’t hesitate to ebay message us.